When the pulsating pressure is high, it often becomes unusable in a short period of time, but the durability is greatly improved by using this device. The results of the comparison test between the conventional type and this tester are as follows.
Working Pressure Gauge: 100φ x 10 MPa Reference Pressure 5 MPa
Pulsation ±0.5 MPa Frequency 1200/min Amplitude ±0.7 mm
General type: Needle goes up 5° in about 70 hours.
Glycerin Encapsulated Type: Needle Up 5° in 2200 Hours
With an endurance ratio of more than 30 times, the deflection of the pointer during operation is approximately 1/6. In addition, since it has the same mounting hole as the general product, it is interchangeable even when the conventional anti-vibration type is used. Glycerin solution is equivalent to class 4 and class 3 petroleum in the Fire Defense Law, so there is little risk of fire, and since it is harmless, it can be used for food industry.