Rapid and Economical Catalytic Reaction Screening Container for Reducing the Cost of Combichem Synthesis
SynFlexTM Catalyst screening container for aluminum block thermostatic bath with stirrer. By using this container, atmospheric pressure and high-pressure reaction screening can be easily performed.
Since high-throughput screening can be performed easily, the cost of equipment installation during large-scale research can be reduced.
The container has a temperature sensor insertion hole for monitoring and controlling the temperature. Reflux of the cold finger prevents solvent loss.
The vial can be set in the vessel hole in a short time to achieve a uniform temperature in the atmosphere.
After manual gas replacement (vacuuming + inert gas filling) with a ball valve and a pressure gauge, reactant gases (such as hydrogen) can be filled.
Type HIP-7518 is for 2 m HPLC vials with 18 seats. Can be used with an open top (can be used at high temperature and pressure) or an aluminum cap (septum set).
Specifications
Composite scale: 0.3 ~ 1.3 mL x 18
Maximum working pressure: 5 MPa (at 230 degrees C)
Operating temperature range: Room temperature to 230 degrees Celsius (excluding when using septum)
Stirring system: Magnetic stirrer (RCH -1000 type)
Features:
Reflux: Cold finger (return with tap or cooling water)
Gas replacement: Ball valve (3-way type for switching) + pressure gauge
Pressure indication and relief valve: Filling of reactant gas after purging - 100/0/2400 kPa, Relief adjustment range: 0.34 ~ 2.41 MPa
Standard:
Others: With temperature sensor insertion hole, positioning hole
Container dimensions (mm): height 110 (without protrusions), body cylinder: phi 75 x 44 H
Vial: 2 ml HPLC vial
Dimensions (mm): phi 12 x 32 H crimp type
Stirrer dimensions (mm): phi 3.0 x 6.4
Connection Diameter: Cold Water Connection Port/Purge Port: Outer Diameter 7.62 mm Hose Port, Reactive Gas Inlet: Outer Diameter 1.58 mm (1/16 ") Hose made of SUS 316
Wetted part materials: SUS 316 (Body, Cover), Viton (O-ring), EPDM (relief valve seal), Glass (vial)
*Use a single-holder BBS -1 HLD to heat the container.
*The O-ring made by Perfro ® needs to be replaced for temperatures above 200 degrees Celsius.
*The EPDM O-ring must be replaced when circulating cooling water below 0 degrees Celsius.
*Vials and stirrers are sold separately.
*Depending on the sample and conditions of use, this may fall under the Ministry of Economy, Trade and Industry's High Pressure Gas Safety Act.
*Reflux at low temperatures requires a cooling water circulator.
*Conversion of the pressure gauge and spring kit is required to operate at 5 MPa.