System: Air-cooled electron cooling/external open system circulation/integral (S: Separate) Operating temperature range: 0℃ to +70℃ Temperature control accuracy: +/- 0.1℃ Cooling capacity (at liquid temperature 20℃): 163kcal/h(189W) Pump performance (50Hz): Maximum flow rate: 11L/min, Maximum discharge pressure: 78.4kPa Outer dimensions: Integral: 371 x 440 x 380 Circulation mouth nipple diameter: Outer diameter φ12.7 Thermo module number, 8 pcs Power supply: AC100V